Cat C280-8
Marine
Specifikationer
Generator Set Specifications
Minimum Rating | 2350 ekW (2938 kVA) |
Maximum Rating | 2420 ekW (3025 kVA) |
Frequency | 50 Hz or 60 Hz |
Speed | 1000 rpm (50 hz) or 900 rpm (60 hz) |
Emissions/Fuel Strategy | EPA Tier 2, IMO II |
Engine Specifications
Aspiration | Turbocharged-Aftercooled |
Bore | 280 mm |
Stroke | 300 mm |
Displacement | 148 l |
Governor Type | Electronic |
Fuel System | EUI |
Compression Ratio 50 Hz | 13.1 |
Compression Ratio 60 Hz | 13:1 |
Engine Model | In-line 8, 4-Stroke-Cycle Diesel |
Generator Set Dimensions
Length | 8040 mm |
Width | 1961 mm |
Height | 3937 mm |
Weight - Estimated | 11340 kg |
C280-8 Auxiliary / DEP (2530, 2300 bkW) Tier 4 Spec Sheet
Download (PDF)Fördelar och funktioner
A3 ecu
Advantages
CAN J1939 data link Waterproof connectors, Maintenance-free, Backup ECU for redundant governing
Electronic Advantages
Load feedback, Programmable droop, Adjustable gain, Adjustable fuel/air ratio control, Histograms of engine operation, Cat Messenger display presents diagnostics and other engine parameters
Data Advantages through J1939 Link
Engine speed, Boost pressure, Throttle position, Fuel consumption rate, Inlet manifold temperature, Diagnostic codes and events, Configuration, Desired engine speed, Battery voltage, Engine load, Lifetime totals — engine hours, fuel burned, idle fuel, idle hours, Trip totals — average fuel rate, idle fuel, idle hours, engine hours, fuel burned, trip reset
Customer interface panel
Advantages
Interfaces with standard Cat® Marine Monitoring System (PLC in Price List), Provides visual indication of ECU functionality, Accepts 4 — 20 mA or PWM remote throttle speed input, Marine alarm and protection
Electronic unit injectors
Advantages
“Drop-in” installation, No threaded fuel connections, High pressure inside injector only, Does not require double wall fuel lines or leak collection device, Injector synchronization not required